• On/off control. Press for 'on', release for 'off'. Battery check tone at switch on
• 3 position function select switch:
P - Power Mode for detecting live imbalanced cables
R - Radio Mode for detecting re-radiated radio signals
G - Generator Mode for detecting conductors carrying the signal generated by the SGV Signal Generator or from the Sonde Transmitter
• Sensitivity Control
• Push button to activate depth measurement - XD only
Display
Large, easy to read liquid crystal display. Shock resistant, mounted behind poly carbonate lens for maximum protection. The display indicates:
• Signal strength.
• Battery conditiononly..
• Confirmation of selected mode.
• Depth in G mode - XD only.
Frequency :P - 50-400 Hz R - 15-20 kHz G - 33 kHz
Depth of detection (Applicable For Model XD)
The Cable Avoidance Tool will typically detect at the following depths: P - 3 metres R - 2 metres G - 3 metres
Depth measurement - XD only
Range: 0.25 - 3.0m (line) 1.0 - 6.0m (sonde)
Batteries 8 x AA - Typical life 40 hours
• Audio feedback on button press.
• Audio frequency drops to indicate a good connection.
• Audio frequency on induced mode changes with power level.
• Audio output pulsed to indicate pulsed mode.
• Low battery indication.