SI-100 Continous Gas Leak Detection : Fixed Gas Detector

SI-100 Gas Detection Equipment

SI-100 fixed gas detector is installed at places where potential gas hazard exits to measure gases such as oxygen, toxic gas and combustible gas (CH4, O2, CO, H2S, SO2, NH3, H2). It shows not only the concentration of gas but also diagnostic result of the unit itself through the LCD display and can be connected to the controller with a standard 4-20mA analog output communication or RS-485 digital communication.

SI-100 fixed gas detector is air, dust and explosion proof. It is certified with TRTS certification from Russia

The SI-100 fixed gas detector shows the concentration of gas and diagnostic result of the unit through its LCD display based on built in calibration mode.

There is also the option of an SI100C economy model without display

SI-100D is a fixed gas detector for monitoring LPG/LNG leaks in commercial kitchens.

Applications:

Steelworks, petrochemical, refining, shipbuilding, wastewater treatment plants and septic, mining, power, agency, confined space work area

Specifications
Product Specification

Part No

SI1000910

SI1000110

SI1000210, SI1000510, SI1000310, SI1000710

SI1000410

Measuring gas

Combustible

O2

CO, H2S, SO2, NH3

H2

Measuring Type

Diffusion Type

Measuring Method

Catalytic

IR

Galvanic

Electrochemical cell

Electrochemical cell

Measuring range

0~100%LEL

0~100%LEL

0~30%VOL

CO: 0~500ppm,
H2S: 0~100ppm,
S02: 0~20ppm,
NH3: 0~100ppm

0~1,000ppm

Sensor life time

> 5 years

> 2 years

< 2 Y ears

> 2 years

> 2 years

Response time

< 15sec / 90%scale

<30sec/90% scale (IR)

< 15sec/90% scale

< 30sec/90% scale

< 30sec/90% scale

Accuracy

±3%/Full scale

Resolution

1%LEL

0.1%VOL

1PPM

1PPM

Parameter Control

SI100: Front 3 magnetic switch (calibration, maintenance, alarm setting)
SI100C: One switch interface (calibration), console set available (option)

Operation mode display

SI100: Digital LCD display with blue backlight, 4 Indicator LED
SI100C: 2-LED (operating & zero cal., span cal.)

Alarm display

Only in SI100: Visual: LCD alarm display with backlight, Indicator LED

Alarm output signal

Only in SI100: Relay contact (Max 30Vdc, 5A) when Alarm occurred

Alarm level set

Only in SI100: Programmable within detection range

Output signal

Analog: 4-20mA

Cable/Distance

Power + Signal cable: 3-wire CVVSB 1.5sq or AWG20/2,500m max,

Conduit connection

NPT 3/4" (2way)

Mounting type

Wall mount

Program set mode

Only in SI100: "Alarm value (1,2,3 alarm), Alarm time (instant & delay)1~30min, Alarm dead band, Relay output on/off

Operating temperature

-20˚C ~ +55˚C

Operating humidity

5% to 95% RH(Non-condensing)

Operating power

SI100: 10~34VDC 500mA, SI100C: 9~34VDC

Material

Aluminium, Stainless steel (STS304)

Size

SI100: WHD 135 × 164 × 110 mm SI100C:  WHD 102 x 137 x 87 mm

Weight

SI100: 1.9kg, SI100C: 1.0kg

Approval

Ex d IIC T5 (IP65)_Korea Ex, IECEx, ATEX, CNEx, INMETRO, PESO

Options

SI100: Battery type, Built-in Light bar, Moveable SI100C: Console

 

Features
Features
  • Large LCD display with blue backlight can measure the concentration of the flammable gases, toxic gas and oxygen gas
  • Explosion proof structure
  • Water/Dust Proof
  • Easy magnetic bar operations
 
 
Product Info Downloads
Product Info Downloads

Product Information files contain the essential technical detail you need to make informed decisions on any particular product. Simply click on a title to download a PDF copy of that file. If you wish a hard copy of a brochure, technical advice on any product or a demonstration then please contact us. We're always happy to help!

Title
File Type
File Size
Last Uploaded
application/pdf
121.44 KB
February 22 2019 11:26:00
 
 

Related Products

Get In Touch
Want to Know More About our Products ?

Contact us today to find out more. We have our sales representative ready to help you with any subject matter related to our products

Top Categories