Advanced buried plb pipe duct route tracing system for telecom project & maintenance applications.
To locate route of non metallic hdpe conduits locate blockages in existing telecom ducts route tracing armored telecom cable depth measurement of existing or new laid cables.
System Guide & Illustration
Receiver Specifications
Transmitter Specifications
Buzz Box Specifications
System Guide 1 :
Locate & Trace Underground Non Metallic Hdpe Pipes & Blockages In Existing Laid Ducts.
The SONDE operating at 512Hz is attached to the CTRAK Traceable Duct rodder unit & is pushed inside the non metallic HDPE Conduit or any other line until it stops due to blockage in HDPE pipe or because of entry into next manhole. The CTRAK contains a 1 sq mm tracer which is energized by the Line excitor at 8/16/32 or 64kHz. The digital receiver is then set to receive frequencies at 8/16/32 or 64kHz to trace direction and route of line in the Line Tracing Mode. Once the trace is completed until the line trace starts to fade, the receiver setting is changed to the Sonde Tracing Mode to receive 512Hz frequency transmitted by the SONDE or any other customized frequency which can then be used to pin point exact point of blockage in HDPE conduit or manhole location.
Visual illustration (CTRAK) :
Underground Locating of pipes/ducts using PipeTraker Traceable Duct Rodder.
![]() |
![]() |
![]() |
![]() |
| Step 1 : Attach sonde to front of the rod. Insert rod into manhole and push into metallic or non metallic pipe/duct which is to be route traced. |
Step 2 : The terminal box of the CTRAK provides the connection to the inbuilt copper trace wire of the duct rodder. |
Step 3 : Energise the traceable duct rodder with any frequency such as 8/16/33/64/65/133 KHz etc using any signal excitor/ transmitter. |
Step 4 : Trace route & depth of buried duct in line tracing mode and blockage points of underground conduit in sonde mode using digital receiver. |
The SONDE operating at 512Hz is attached to the CTRAK Traceable Duct rodder unit & is pushed inside the non metallic HDPE Conduit or any other line until it stops due to blockage in HDPE pipe or because of entry into next manhole. The CTRAK contains a 1 sq mm tracer which is energized by the Line excitor at 8/16/32 or 64kHz. The digital receiver is then set to receive frequencies at 8/16/32 or 64kHz to trace direction and route of line in the Line Tracing Mode. Once the trace is completed until the line trace starts to fade, the receiver setting is changed to the Sonde Tracing Mode to receive 512Hz frequency transmitted by the SONDE or any other customized frequency which can then be used to pin point exact point of blockage in HDPE conduit or manhole location.
System Guide 2 :
For Route Tracing Of Underground Armored Electric Cables, Armored Ofc & Metallic Utility Pipes.
The line excitor as shown above is connected in conductive locate mode through a jaw clamp to the armoring of the non-energized electric metallic cable , armored Optical Fiber Cable (OFC) or any other metallic utility pipes/line at 8/16/32 or 64KHz which is route traced using the Line Tracing mode of the digital Receiver.
System Guide 3 :
For Locating Energized Power Cables.
The Digital Receiver is set to 50 Hz for locating highly energized underground power cables. A three step procedure guides the user to locate peak energized power signals received from power cables in step 1, line trace the route of energized power cables in Step 2 and measure Depth in Step 3. Assists in avoiding cutting into any power cables ensuring safety and also eliminates interference or incorrect locates in line tracing mode (as described in system guide 2) that can be caused by surge fields from HT cables.
| Frequency | Sondes at 16 Hz & 512 Hz & 8kHz & 2 "sniffable" frequencies | ![]() |
| Line trace | 8, 16, 32 & 64 kHz | |
| Output LCD screen | Index, Peak locate, Line, Sonde, Track, Power, Sniff,Depth | |
| Automatic depth detection | 25 feet /7.6 meters ; accurate upto 5% of depth | |
| Controls | 4-way thumb switch: Power on/off, Gain, Screen select | |
| Speaker output | Variable rate click; headphone jack. Sound can be muted | |
| Power source | 6 AA Alkaline | |
| Battery life | 30-40 hours (depends on backlight usage) | |
| Operating temperature | -20 to +130º F / -29 to +54º C | |
| Weight | 2.7 kg | |
| Size | 81 cm x 20 cm x 11 cm | |
| Locate Accuracy | 5% of Depth, depending on depth | |
| Depth Accuracy | 5% of Depth with undistorted signal, with no | |
| Adjacent Signals | Upto 14ft/4.3m | |
| Depth Range | Line -up to 3 m at 5% depth accuracy | |
| Up to 25 ft / 7.6 m at 10% depth accuracy | ||
| Sonde - up to 15 ft (with FV-10) | ||
| Sonde - up to 60 ft / 18.3 m (with FV-40) | ||
| Item Code | ST-DR 2200 |
| Frequency | 512 Hz | ![]() |
| Tone type | Continuous | |
| Power source | AAA 1.5V Battery | |
| Battery life | 8 hours((for continuous uninterrupted use) | |
| Size | 19 mm x 89mm | |
| Range (cast iron) | Up to 10 ft | |
| Range (non-metallic) | Up to 15 ft | |
| End Adaptor | Female M12 | |
| Item Code | ST- FV10 |
| Operating Modes | Conductive & Inductive | ![]() |
| Power | 3watts maximum, Lo and Hi power for each frequency, uses 6 "C" alkaline batteries, battery life appox 10 hours continuous |
|
| Control | Rotary switch ; Off plus 8 frequency/power selections | |
| Indicators | Low battery LED, Ground quality current meter | |
| Operating Temperature | 0 – 50 deg C | |
| Dimensions | 240mmx190mmx110mm | |
| Item Code | ST-BB |