PS3500 Power Analyzer
The PS3500 provides simplicity, reliability, and complete answers in the analysis of single & three phase electric power and energy analysis.
• Analyze how energy is used and what it costs.
• Evaluate quality of power.
• Troubleshooting equipment.
Industry’s Highest Safety Rating CAT IV
Complete power/energy/cost analysis.
  Measures voltage, current, KW, KVA, KVAR, true power factor, displacement
  power factor, KWH, elapsed and estimated cost and duty cycle. Complete
  logging and manual waveform capture ability.
Compatibility with any power system. Single phase, two phase, three phase
  (wye, delta, 4 wire delta, open delta, grounded delta), 3PT/2PT, and 3PT/3CT.
  DC, 50Hz, 60Hz, 400Hz, 45-66Hz, and 360-440Hz. Phase-phase, phase-neutral,
  and regenerative systems. All systems up to 600Vphase-neutral (800V phase-
  phase)and with voltage probes, direct connection to 4,160V and 12,500V.
Harmonic Analysis. Performs spot checks and logging of THD and analysis out   to the 50th   harmonic on all inputs.
Wireless Communications with Bluetooth technology.
“Foolproof” Connections with SureStartTM patent-pending technology.
Provision for Removable Memory with SD.
• Unmatched portability and ease of use. Weighs less than 1 kg. SurePowerTM   technology takes the worry out of powering the meter and its accessories.   SureSenseTM technology insures current readings are correct, even when  mixing   current probes. Keypad and display for simple, quick, portable readings.



Provided with power analysis software tool that performs complete presentation and analysis of power consumption and Report Writer software which provides concise summaries including comparisons of performance.




Measurement Rate:
Analyzes two cycles per second of each voltage and current input at 16 µs; uses 130 samples per cycle @ 60 Hz. All measurements updated once per second
Voltage Measurement Ranges:
1-600 Vrms steady-state(direct input);
1-600 Vdc or 600-5,000 Vrms with 5KVP probes,
or 600-15,000 Vrms with 15 KVP probes.
Display Range: 1-6MV (using input ratios)
Meter Display Resolution: 0.1V
Accuracy: 0.5% of reading ±0.3 Vrms
Current Measurement Ranges:
With HA5: 0.02-5A
With HA100: 0.1-100A
With HA1000: 1-1000A
With FX3000: 10-3000A
With FX5000: 100-5000A
With DC600: 5-600 A DC
Display Range: 1mA-6MA(using input ratios)
Meter Display Resolution:0.1A
Accuracy:0.5% of reading plus accuracy of probe
Phasor diagram: via PC
Imbalance: via PC
Frequency Measurement:
Range: DC, 45-66Hz, 360-440 Hz fundamental
Display on Meter
Accuracy:±0.5%
Harmonics Measurement:
45-3000Hz(50th harmonic @ 50/60 Hz, 7th @ 400Hz);
THD Accuracy:
1%;Displays THD and individual harmonics through 25th harmonic of all signals. PowerSight Manager Software displays harmonics through 50th harmonic for both units on a PC;
Power, Energy, Cost, Power Factor:
VA,VAR, True Power Factor, Displacement Power Factor, Phase Lag Angle, Energy kWh, Energy cost in $, Waveform snapshot.
Display Range: 1 watt-60MW (using input ratios)
Accuracy: 1% plus accuracy of current probe
Transient Detection: one channel
Logging Period (resolution) User selectable from 1 second — 99 minutes
Logging Duration(length of monitoring session) User selectable up to 2 years according to memory allocation
Power Requirement: 12 VDC@500mA, wall-mount power supply included. Internal Ni-Cad battery operates 8-10 hours after full charge
Size:196x40x54mm
Weight: 0.5kg